Supply Installation Testing and Commissioning of Air Cooled Packaged Air Conditioning Units Including Refrigerant Piping GI Ducting Electrical Works Insulation Air Distribution System and Associated Works at NDDP MPDD Kalpakkam
Bhabha Atomic Research Centre · Kalpakkam, Tamil Nadu · HVAC & Cooling · open
Key facts
- Tender value: ₹1.0Cr
- EMD: ₹2.0L
- Published: 03 Nov 2026
- Closing date: 19 Nov 2026
- Status: open
- Status as of: 10 Nov 2026 01:14 UTC
- Ministry: Department of Atomic Energy
- Department: Bhabha Atomic Research Centre Facilities
- Office: MPDD, Kalpakkam
Description
Supply, installation, testing and commissioning of air-cooled packaged air conditioning units, including refrigerant piping, GI ducting, electrical works, insulation, air distribution system and associated works at NDDP/MPDD Kalpakkam. Estimated cost is Rs. 1,01,79,750; completion period is 3 months.
Eligibility & requirements
- Startup relaxation: No
- MSE relaxation: No
- Certifications: Class-III Digital Signature Certificate
- Documents required: Earnest Money Deposit instrument, Technical bid documents, Financial bid in the prescribed BOQ format, Signed and sealed pre-bid clarification documents, if any
New to these terms? Read how tender eligibility criteria work.
Commercial terms
- Bid type: Item Rate
- Evaluation: Item wise
- Make in India (MII): No
- MSE preference: No
Line items (42)
- Supply, installation, testing and commissioning of air cooled microprocessor controlled Packaged Air conditioners 11.0 TR nominal capacity, 7480 m3/h (4400cfm) - 4 Nos (Working) & 2 Nos (Stand by)equipped with scroll hermetically sealed compressors, cross hatched copper tube lanced fins condenser, evaporator fan, thermostatic expansion valve DX-type evaporator, filter, temperature control, etc., as per the scope of work. — Qty: 6 Nos.
- Supply, installation, testing and commissioning of air cooled microprocessor controlled Packaged Air conditioners 16.5 TR nominal capacity, 11220 m3/h (6600cfm) - 4 Nos (Working) & 2 Nos (Stand by)equipped with scroll hermetically sealed compressors, cross hatched copper tube lanced fins condenser, evaporator fan, thermostatic expansion valve DX-type evaporator, filter, temperature control, etc., as per the scope of work. — Qty: 6 Nos.
- Supply and installation of complete Set of copper tubes of size OD 1 1/8" (28.58 mm) with wall thickness of 1.83 mm & OD 5/8" (15.88 mm) with wall thickness of 1.02 mm as per specification and scope of work. — Qty: 90 RM
- Supply and installation of complete Set of copper tubes of size OD 7/8" (22.22 mm) with wall thickness of 1.40 mm & OD 5/8" (15.88 mm) with wall thickness of 1.02 mm as per specification and scope of work. — Qty: 90 RM
- Supply and installation, 4C X 25 sq.mm 1.1kV grade Copper conductor PVC insulation flat wire armored PVC outer sheath cables as per the detailed specification. — Qty: 100 RM
- Supply and installation of 4C X 16 sq.mm 1.1kV grade Copper conductor PVC insulation flat wire armoured PVC outer sheath cables as per the detailed specification. — Qty: 100 RM
- Supply and installation of 3C X 2.5 sq.mm 1.1kV grade Copper conductor insulation round wire armoured PVC outer sheath cables as per the detailed specification. — Qty: 180 RM
- Supply and installation of 3C X 1.5 sq.mm 1.1kV grade Copper conductor insulation round wire armoured PVC outer sheath cables as per the detailed specification. — Qty: 180 RM
- End Termination of the 4C x 25 Sq.mm including cable gland ear thing Copper Conductor PVC/XLPE Insulated and FRLS sheathed armoured UG Cable using Single Compression, Heavy Duty, Siemens type Brass Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. — Qty: 12 Nos
- End Termination of the 4C x 16 Sq.mm including cable gland earthing Copper Conductor PVC/XLPE Insulated and FRLS sheathed armoured UG Cable using Single Compression, Heavy Duty, Siemens type Brass Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. — Qty: 12 Nos
- End Termination of the 3C x 2.5 Sq.mm including cable gland earthing Copper Conductor PVC/XLPE Insulated and FRLS sheathed armoured UG Cable using Single Compression, Heavy Duty, Siemens type Brass Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. — Qty: 12 Nos
- End Termination of the 3C x 1.5 Sq.mm including cable gland earthing Copper Conductor PVC/XLPE Insulated and FRLS sheathed armoured UG Cable using Single Compression, Heavy Duty, Siemens type Brass Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Copper crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. — Qty: 12 Nos
- Supply and laying of 8 SWG copper earth wire double run between Indoor and outdoor units of PAC system as per scope of work and as directed by Engineer - in- Charge. — Qty: 200 RM
- Supply and fixing of 63A rating, four pole, 415 V MCB 'C' series, Conforms to: IS 13947-3 in the Packaged Air conditioners control panel, complete with connections, testing and commissioning etc., all complete as per specification and as directed by Engineer in charge. — Qty: 12 Nos
- Supply and laying of 25 mm size CPVC pipe (SDR 11) conforming to IS:15778 including fixing with required specials, fittings including couplings and T-connection, 1.0 m with sloping, bends etc., all complete as per specification — Qty: 75 RM
- Supply, fabrication and erection of GI ducting with 22 gauge Class VIII G.I sheet including providing of vanes, M.S angle support, angle flanges, anchor fasteners, grill collar, tees, bends, etc. as per the scope of work. — Qty: 450 Sqm
- Supply, fabrication and erection of GI ducting with 20 gauge Class VIII G.I sheet including providing of vanes, M.S angle support, angle flanges, anchor fasteners, grill collar, tees, bends, etc. as per the scope of work. — Qty: 175 Sqm
- Supply, fabrication and erection of GI ducting with 18 gauge Class VIII G.I sheet including providing of vanes, M.S angle support, angle flanges, anchor fasteners, tees, bends, etc. as per the scope of work. — Qty: 60 Sqm
- Supply and install GI Flat oval ducting with 22-gauge Class VIII GI sheet metal Factory Fabricated with fittings, Gripple supports, the factor of gripple to suit to duct weight, with necessary anchor fasteners and hook arrangements with suitable rod thickness, etc., including bend, coupling, transfer piece, confirming SMACNA standards. Factory made duct joints to be provided. For All exposed ducts thermal insulation to be at inner surface of the duct. (Insulation qty included in separate line item) — Qty: 60 Sqm
- Supply and install GI Flat oval ducting with 20-gauge Class VIII GI sheet metal Factory Fabricated with fittings, Gripple supports, the factor of gripple to suit to duct weight, with necessary anchor fasteners and hook arrangements with suitable rod thickness, etc., including bend, coupling, transfer piece, confirming SMACNA standards. Factory made duct joints to be provided. For All exposed ducts thermal insulation to be at inner surface of the duct. (Insulation qty included in separate line item) — Qty: 40 Sqm
3 tender document(s) available — sign up to download.
Related tenders
- Split Air Conditioner, Wall Mount Type (V3) ISI Marked to IS 1391 (Part 2) — HVAC & Cooling · Gujarat · ₹4.7L
- Split Air Conditioner, Wall Mount Type (V3) ISI Marked to IS 1391 (Part 2) — HVAC & Cooling · Jammu and Kashmir
- Supply, Installation, Testing and Commissioning of 17 Unitary Air Conditioners (Window AC) — HVAC & Cooling · Punjab · ₹6.7L
- Supply of Split Air Conditioners and Servo Motor Operated Automatic Line Voltage Correctors — HVAC & Cooling · Ladakh
- Split Air Conditioner, Ceiling Mount Type (Cassette) (V3) ISI Marked to IS 1391 (Part 2) — HVAC & Cooling · Manipur
- Air Purifier — HVAC & Cooling · Delhi
- Tender for AC works at SBI High Court branch Prayagraj — HVAC & Cooling · Uttar Pradesh · ₹6.0L
- Supply, Installation, Testing and Commissioning of Split Air Conditioner, Wall Mount Type (V3) ISI Marked to IS 1391 (Part 2) — HVAC & Cooling · Uttarakhand