Supply and erection of road light pole and installation of road light at various palaces Raisinghnagar
Municipal Board, Raisinghnagar · Raisinghnagar, Rajasthan · Electrical Equipment & Supplies · open
Key facts
- Tender value: ₹1.4Cr
- EMD: ₹2.9L
- Published: 05 Nov 2026
- Closing date: 15 Nov 2026
- Status: open
- Status as of: 07 Nov 2026 04:02 UTC
- Department: Department of Local Self Government
- Office: Office of Municipal Board of Raisinghnagar
Description
Supply, erection, installation, testing and commissioning of road-light poles, LED street lights, cabling, earthing, control panels and associated works at various places in Raisinghnagar, Rajasthan.
Eligibility & requirements
- Startup relaxation: No
- MSE relaxation: No
- Certifications: BIS, IS 10322, NABL, CPRI, UL 467, IS/IEC 62561-2
- Documents required: NABL-accredited manufacturer test report for HDPE pipe, OEM in-house NABL laboratory testing documentation for cables, BIS certification and trademark certification for LED luminaires, UV stabilization report for the luminaire cover, LM79/LM80 certificate or report and OEM product/accessory warranty, CPRI test certificates for the electrical panel, OEM test certificates confirming earthing rod standards
New to these terms? Read how tender eligibility criteria work.
Commercial terms
- Bid type: Percentage
- Evaluation: Percentage rate
- Make in India (MII): No
- MSE preference: No
Line items (17)
- Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . A) Excavation of Pit for Foundation Size upto required depth from Ground level B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. G) Providing and Laying Reinforce cement Concrete — Qty: 260 Each
- Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular crosssections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB — Qty: 260 Each
- Double arm overhang — Qty: 12 Mtr
- Single arm overhang — Qty: 260 Mtr
- P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 63 mm — Qty: 6250 Mtr
- SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear ear — Qty: 15 Sq Mtr
- 16.0 Sq. mm 4 core — Qty: 8350 Mtr
- 35.0 Sq. mm 3.5 core — Qty: 800 Mtr
- Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase p — Qty: 284 Each
- Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 1.5 Sq. mm 3 core — Qty: 2600 Mtr
- Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . — Qty: 12 Set
- Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e), (f) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts ( c) Connect the ro — Qty: 12 Set
- Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 6 SWG G.I. ( Hot Dipped ) Wire — Qty: 7000 Mtr
- 4 x 16.0 sq.mm — Qty: 530 Set
- 3 x 35.0 sq.mm — Qty: 24 Set
- Supply installation testing & commissioning of IK08 & IP56 Three phase 440V 50Hz, 7.5 kw capacity centralized control and monitoring system panel (CCMS) made of fire retardent SMC steel material having lock & suitable for schedule on/off of street lights having following provision: Inbuilt on chip integreted energy metering with 3 nos CT having class 1 accuracy, Three phase auto phase selector power supply with withstanding capability up to 500 VAC, Instant mode, Fixed Mode, Astronomical Mode, Hybrid Mode, Interval Mode, Offset in Sunset and Sunrise Timing for scheduling, Provision for measurement of all three phase electrical parameters like voltage, current, power factor, power, frequency, energy with atleast class 1 accuracy and compliant with IS13779 standard, UV-OV protection, backup battery 8 hrs, Andriod/iOS app and software to operate form computer, provision to add display device externally, support for RS485 communication, inbuilt GSM/GPRS 4G modem with 2G fallback, Real time — Qty: 12 Each
- Annual Maintenance Charges of the Sim Card and Software Charges of the CCMS Controller for 1 year (After 2 year of Comprehensive Warranty and O&M) Charges for providing a comprehensive onsite warranty including all preventive and corrective maintenance, repair/replacement of defective components or units, onsite support, spare parts, and any trave expenses. The warranty covers all hardware, software, 'accessories, and consumables supplied under the contract, ensuring uninterrupted operation as per tender requirements. (After 2 year) — Qty: 12 Per CCMS Per Year
2 tender document(s) available — sign up to download.
Related tenders
- SUPPLY OF V.F TRANSFORMER OF RATIO 470:600 OHMS (CYLINDER TYPE) — Electrical Equipment & Supplies · Madhya Pradesh
- Handheld Rechargeable Pocket Torch — Electrical Equipment & Supplies · Madhya Pradesh
- Procurement of Digital Dial Indicator and Stainless Steel Flexible Magnetic Base stand — Electrical Equipment & Supplies
- Erection of lighting line for mine lighting purpose at R-VI seam and various places coal depot, DDU, Agent office at Khottadih OCP — Electrical Equipment & Supplies · West Bengal · ₹9.9L
- Procurement of Electrical instruments/Equipments and machinery for Electrical, Repairing, Fabrication and other electrical works at Gumgaon Mine — Electrical Equipment & Supplies · Maharashtra · ₹1.9L
- Work of re-organisation of generator line in different rooms of Bankola Area offiece. — Electrical Equipment & Supplies · West Bengal · ₹1.5L
- Diversion of 6.6KV O/H Line at Jharna Face due to increase in water level and widening of Haul Road for feeding power to 4000GPM Motor Pump in SOCP Muraidih AMP Colliery. — Electrical Equipment & Supplies · Jharkhand · ₹1.2L
- Installation of earth pits at different substations of Jambad Colliery — Electrical Equipment & Supplies · West Bengal · ₹5.1L