Description
Open tender for special repairs and renovation comprising civil and electrical works in Rooms W-322 and W-325 of DIT at Nau Sena Bhawan, Delhi Cantt. The estimated cost is Rs. 24.03 lakh, completion period is four months, and the tender requires an EMD of Rs. 48,060.
Eligibility & requirements
- Startup relaxation: No
- MSE relaxation: No
- Certifications: Chartered Accountant certification with UDIN for turnover documents, Performance certificate certified by an officer not below the rank of Executive Engineer or equivalent and/or client
- Documents required: Undertaking for Near Relatives Working In DRDO (Appendix-B), Certificate for acceptance of terms and conditions of tender (Appendix-C), Bank Guarantee for Earnest Money Deposit (Appendix-D), Undertaking for Banned Business (Appendix-E), Annual Turnover duly audited by Chartered Accountant (Appendix-F), Declaration for Bidding Capacity (Appendix-G), Existing commitments (Appendix-H), Undertaking for JV consortium (Appendix-J), Performance Certificate (Appendix-K), Supporting documents for bidding capacity, including copies of LOI/work orders, Audited and certified financial statements for the previous five consecutive years, Certificates of satisfactory performance for qualifying similar works
New to these terms? Read how tender eligibility criteria work.
Commercial terms
- Bid type: Two Packet Bid
- Evaluation: Percentage rate
- Make in India (MII): No
- MSE preference: No
Line items (21)
- 2 — Qty: 4 5
- Workstation: Supplying, fixing and placing as per user requirement of workstation of size 1350Wx 600Dx750H. (Standalone workstation) The system shall be a desk-based system with a platform under structure made up of a combination of MS. tubes and plates. These terminating leg structure shall be in M.S. CRCA sheet/ tubes/rods finished with epoxy powder coating of the approved colour as per the Engineer in charge. The MS ERW tube of legs of table should be of size of 50 mm x 50 mm x 1.2mm thk. The base of the MS tube is to be fitted with a Glide plate 5mm thk HR over which a straight M8 leveller is to be fitted with bottom translucent cap , allows for adjustment of the height by 50mm, support brackets 3 mm thk HR are to be welded on top side of Leg for fixing the table top. The terminating legs will be provided with modesty panels of 300 mm from worktop in front and both sides along the complete width/depth. These modesty panel shall be of Metal 1.2 mm thick CRCA. Worktop shall be made o — Qty: 78 Each
- Workstation chair Supplying, fixing and placing as per user requirement of the workstation chair seat/back assembly: The cushioned seat assembly consists of seat base moulded in Polyurethane foam & upholstered with polyester fabric. The cushioned back assembly consists of back moulded in Polypropylene & upholstered with polyester fabric. Back Size : 43.5 cm. (/1/) x 50.0 cm. (H) , Seat Size : 45.5 cm. (W) x 47.0 cm. (D) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam used in seat and back cushion is moulded in Density Min 48 kg/m3, and hardness load 15 ± 2 kgf as per IS:7888 for 25% compression.TILT MECHANISM, SPINES & SPINE CONNECTOR: The seat and back are firmly connected to the base frame. The variable tilt angle recline motion can be adjusted with Tilt Limit feature. ADJUSTABLE ARMRESTS: The assembly consists of armrest housing sliding over the armrest structure, both moulded in Polypropylene: The height adjustment feature should be button operated having adjustmen — Qty: 78 Each
- Regrading terracing of mud phaska covered with tiles or brick, in cement mortar by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement : 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded), all complete as per direction of Engineer-in- Charge. — Qty: 20 sqm
- Providing and laying Vitrified tiles in floor with size of Tile 500x500 mm (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). — Qty: 20 sqm
- Supplying and drawing 2 pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. — Qty: 200 Meter
- Wiring for 3 pin 5/6 A socket outlet along with earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. — Qty: 846 Meter
- Wiring for power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. — Qty: 156 Meter
- Supplying and fixing 6 way (4 + 18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). — Qty: 2 sqm
- Supplying and fixing 63 Amp rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. — Qty: 2 sqm
- Supplying and fixing 16 A to 32 A rating, 240/415 V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. — Qty: 36 Each
- Wiring for circuit/ submain wiring along with earth wire with the 4 X 16 sq. mm + 2 X 6 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. — Qty: 120 Meter
- Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. — Qty: 120 Meter
- Supplying and drawing Single Mode 6 Core Optical fiber cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required. — Qty: 120 Meter
- Supplying, drawing, Testing and commissioning 1 Run of cable of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. — Qty: 124 Meter
- Supplying, installation, Testing and commissioning of 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+ indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 — Qty: 1 Each
- Supplying, Installation, Testing and commissioning of 10 G SFP + Single Mode/Multi Mode small form-Pluggable (SFP) for Network Switches.Must be hot Pluggable, RoHS Complaint, etc.complete as required. — Qty: 1 Each
- Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. — Qty: 1 Each
- Supplying, Installation, Testing and commissioning of Copper Patch Cords of length 3m (10ft) CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. — Qty: 10 Each
- Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. — Qty: 10 Each
2 tender document(s) available — sign up to download.
Related tenders
- UNDER FRAME (LS & LWS PP) — Civil Works & Infrastructure · Tamil Nadu
- Macdamization of road surface at syed Kamalud din Colony wanganpora Eid gah Near UPHC from h/o Ali Mohd upto h/o Nasir Khalel. — Civil Works & Infrastructure · Jammu and Kashmir · ₹15.0L
- Operation of supply valves for the distribution pipe line for piped scheme Babaichya and Narwar with associated works, under jurisdiction of sub division rural, District Rural Division Ajmer (Excluding GST) — Civil Works & Infrastructure · Rajasthan · ₹3.3L
- Construction of Mali Hut at Bimalnag Nursery under CAMPA CAT RATTLE for the year 2026 27 — Civil Works & Infrastructure · Jammu and Kashmir · ₹16.7L
- CONSTRUCTION OF TOILET BLOCK IN SANOUR CITY — Civil Works & Infrastructure · Punjab · ₹9.1L
- Repair of street and drainage in w.no.2 — Civil Works & Infrastructure · Punjab · ₹25.0L
- Repair and renovation of University Library Building at GADVASU, Ludhiana. — Civil Works & Infrastructure · Punjab · ₹9.5L
- P/F Interlocking Tiles St. Baba Jora EO Gurudwara Street Ward No.07 — Civil Works & Infrastructure · Punjab · ₹3.4L