Rejuvenation of Drains
Irrigation and Flood Control · Jahangirpuri, Delhi · Civil Works & Infrastructure · open
Key facts
- Tender value: ₹12.2Cr
- EMD: ₹22.2L
- Published: 05 Nov 2026
- Closing date: 19 Nov 2026
- Status: open
- Status as of: 16 Nov 2026 03:09 UTC
- Ministry: Government of NCT of Delhi
- Department: Irrigation and Flood Control Department
- Office: Civil Division-XV
Description
Rejuvenation of Jahangir Puri drain by construction of a boundary wall, a double-lane steel girder bridge at RD 3200M, recarpeting of the inspection road, and protection of the embankment.
Eligibility & requirements
- Startup relaxation: No
- MSE relaxation: No
- Documents required: Earnest money deposit receipt, Performance Guarantee, Programme chart (Time and progress), Applicable labour licenses, EPFO registration or proof of applying, ESIC registration or proof of applying, BOCW welfare board registration or proof of applying
New to these terms? Read how tender eligibility criteria work.
Commercial terms
- Bid type: Percentage Rate Tender
- Evaluation: Percentage Rate
- Make in India (MII): No
- MSE preference: No
Line items (62)
- Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil. — Qty: 5140 Cum
- Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) — Qty: 64 Cum
- Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. — Qty: 872 Cum
- Foundations, footings, bases of columns, etc. for mass concrete — Qty: 1499 Sqm
- Lintels, beams, plinth beams, girders, bressumers and cantilevers — Qty: 640 Sqm
- Columns, Pillars, Piers, Abutments, Posts and Struts — Qty: 1665 Sqm
- Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. — Qty: 280 Sqm
- Suspended floors, roofs, landings, balconies and access platform — Qty: 98 Sqm
- Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level : Concrete of M10 g — Qty: 819 Cum
- Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level : M-15 grade plain — Qty: 508 Cum
- Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth leve — Qty: 318 Cum
- Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth le — Qty: 37 Cum
- Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth lev — Qty: 363 Cum
- Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth le — Qty: 154 Cum
- Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. — Qty: 178449 Kg
- Boring, providing and installation bored cast in situ reinforced cement concrete piles of grade M-35 of specified diameter and length below pile cap, to carry a safe working loasd not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap) : Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used. 1000 mm dia piles. — Qty: 320 Metre
- Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submitt the design of loading platform for the approval of Engineer-in-charge. Single pile above 100 tonne and upto 150 tonne Safe capacity. Initial test (Test Load 2.5 times the Safe capacity) — Qty: 1 per test
- Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submitt the design of loading platform for the approval of Engineer-in-charge. Single pile above 100 tonne and upto 150 tonne Safe capacity. Routine test (Test Load 1.5 times the Safe capacity) — Qty: 5 per test
- Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS :14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge. Note :- The inclusion of the above item in the schedule of work shall be judiciously decided by the technical sanctioning authority, keeping in view the quality control, type of soil strata & importance of the project. — Qty: 89 Per test
- Supply, fabrication, assembling, hoisting/erecting and fixing in position at lopacations, steel girder using structural steel of rolled single /built up sections confirming to 15:2062- Grads Fe 410 including joist, channel, angles, tee, plates etc. all as per structural drawings and layout per detailed specifications (for materials & workmanship). The item also includes supply, testing of HSFG bolts and compatible nuts and washers. This item also includes all testes fo materials & welded fabricated parts. This item also including necessary equipment for completing the work including necessary scaffolding /staging, launching, Preparation fabrication shop drawings, necessary templates etc. Profile cutting of components to required lengths/width and shapes/profile, smooth grinding/machining of edges/faces/all welding/bolted joints, Necessary welding (electric are welding) for required wield lengths and sizes, Providing and fixing studs of 25mm dia 325 c/c spacing through the length of spa — Qty: 63142 Kg
2 tender document(s) available — sign up to download.
Related tenders
- UNDER FRAME (LS & LWS PP) — Civil Works & Infrastructure · Tamil Nadu
- Improvement such as widening and strengthening of Lalitgiri Museum to Kalianti Bridge via Haribhaktapur-Jerakanda road from 0/000 km to 7/575 km in the district of Kataka under State Plan — Civil Works & Infrastructure · Odisha · ₹20.6Cr
- Renovation of Dharamshala in New Yadvindra Colony, ward no. 20 at Patiala. — Civil Works & Infrastructure · Punjab · ₹42.2L
- Lining/Relining of water course of Outlet R.D 6000-R of mr. no 4 of Newada Disty Village Talwandi Malik, Khattriwala Distt. Patiala — Civil Works & Infrastructure · Punjab · ₹60.0L
- Outsourcing of Labour Part for Erection, Testing Commissioning of New 11KVLT/HTLines on Rail/PCC Poles, Distribution T/Fs, Augmentation/Sagging of ACSR of HT/LT Lines, Cables laying, Guarding, Stay Setfor Various Works — Civil Works & Infrastructure · Punjab · ₹60.0L
- Macdamization of road surface at syed Kamalud din Colony wanganpora Eid gah Near UPHC from h/o Ali Mohd upto h/o Nasir Khalel. — Civil Works & Infrastructure · Jammu and Kashmir · ₹15.0L
- Operation of supply valves for the distribution pipe line for piped scheme Babaichya and Narwar with associated works, under jurisdiction of sub division rural, District Rural Division Ajmer (Excluding GST) — Civil Works & Infrastructure · Rajasthan · ₹3.3L
- Remodelling and renovation Pond Rara Sahib Chowk Somal kheri Np Maloudh — Civil Works & Infrastructure · Punjab · ₹22.3L