MOEI and Fans, RMO Pump Sets i/c Compound Lights at D-II Flats, Vasant Kunj, New Delhi during the year 2026-27.
CE/SE/M4-M45 · New Delhi, Delhi · Electrical Equipment & Supplies · open
Key facts
- Tender value: ₹27.0L
- EMD: ₹54K
- Published: 19 Sep 2026
- Closing date: 25 Sep 2026
- Status: open
- Department: Public Works Department
- Office: EE/M453
Description
Tender for electrical works including wiring, rewiring, fixing switches, sockets, cables, conduits, fans, lighting fixtures, ventilation fans, geysers, LED lights, and other electrical installations at D-II Flats, Vasant Kunj, New Delhi for the year 2026-27.
Eligibility & requirements
- Startup relaxation: No
- MSE relaxation: No
New to these terms? Read how tender eligibility criteria work.
Commercial terms
- Bid type: Open Tender
- Make in India (MII): No
- MSE preference: No
Line items (13)
- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. — Qty: 150 Pts.
- Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. — Qty: 260 Pts.
- Supplying and fixing following size/ modules, GI box as required on the site alongwith modular base & cover plate for modular switches in recess/surface etc. as required. — Qty: 50 Each
- Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. — Qty: 150 Each
- Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. — Qty: 350 Mtr.
- Supplying, installation, testing and commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. — Qty: 48 Each
- Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required — Qty: 48 Each
- Supplying, installation, testing and commissioning of 600 mm sweep ceiling fans without regulator i/c wiring the down rod of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. complete as reqd. — Qty: 12 Each
- SITC of Single Wall Light suitable for retrofit 7.5 Watt Led Lamp. Base of the Wall Light is made of Spun CRCA Sheet and is Circular/oval shape or any other shape as approved . Arm of the wall light is made of mild steel tube. Holder Cap and design is made of CRCA sheet duly approved colour Plated. Base and Arm are duly Powder coated in approved Colour Shade , all colour , shape and model to be approved by the client or Engineer in charge . Mounting Plate is made of CRCA Sheet . Hardware parts are made of mildsteel duly plated. E-27 Lamp holder is fitted in the fixture . Frosted Glass diffuser is provided with the fixture and E-27 LED bulb 7 W in warm/cool light to be provided with the fixture etc as required. — Qty: 24 Each
- SITC of Double Wall Light suitable for retrofit 7.5 Watt Led Lamp. Base of the Wall Light is made of Spun CRCA Sheet and is Circular/oval shape or any other shape as approved . Arm of the wall light is made of mild steel tube. Holder Cap and design is made of CRCA sheet duly approved colour Plated. Base and Arm are duly Powder coated in approved Colour Shade , all colour , shape and model to be approved by the client or Engineer in charge . Mounting Plate is made of CRCA Sheet . Hardware parts are made of mildsteel duly plated. E-27 Lamp holder is fitted in the fixture . Frosted Glass diffuser is provided with the fixture and E-27 LED bulb 7 W in warm/cool light to be provided with the fixture etc as required — Qty: 18 Each
- Supplying, installation, testing & commissioning of 200 mm sizes white body Sweep PVC body Fresh Air Ventilator Exhaust fan with louver shutter in the existing opening of toilet room/kitchen etc i/c connection with 1.5 sqmm FRLS PVC insulated wires and fibre sheets etc as reqd. — Qty: 18 Each
- Supplying, installation, testing & commissioning of 250 mm sizes white body Sweep PVC body Fresh Air Ventilator Exhaust fan with louver shutter in the existing opening of toilet room/kitchen etc i/c connection with 1.5 sqmm FRLS PVC insulated wires and fibre sheets etc as reqd. — Qty: 8 Each
- Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim. — Qty: 56 Each
1 tender document(s) available — sign up to download.
Related tenders
- SUPPLY OF V.F TRANSFORMER OF RATIO 470:600 OHMS (CYLINDER TYPE) — Electrical Equipment & Supplies · Madhya Pradesh
- Handheld Rechargeable Pocket Torch — Electrical Equipment & Supplies · Madhya Pradesh
- Procurement of Digital Dial Indicator and Stainless Steel Flexible Magnetic Base stand — Electrical Equipment & Supplies
- Contact Lever Complete of Tap Changer to M/s. REPL's Pt. No. - S-2506 or to RDSO's Drg. No. - SKEL-4659 (Alt. - 1) — Electrical Equipment & Supplies · West Bengal
- Supply of Mechanical and Electrical Components including Span Bolt and Nut, Motor Protection Assembly, MCCB 63 Amp, Indicating Lamps, PVC Cable, Rubber Packing, and Submersible Pump Lifting Equipment — Electrical Equipment & Supplies · Delhi · ₹6.0L
- Custom Bid for Services - 12 x FXO/FXS, 01 x 10 KVA UPS, 01 x 3 KVA UPS — Electrical Equipment & Supplies · ₹1.5L
- Repair and Refurbishment of Current Transformer of Starter Panel of Fresh Air Ventilation Fante — Electrical Equipment & Supplies · Karnataka
- REPAIR AND REFURBISHMENT OF REMOTE CONTROL UNIT OF C303 — Electrical Equipment & Supplies