Maintenance and Repairs works to mini power pump and hand pump at ward no.1 to 24 in Kulithalai Municipality
Kulithalai Municipality · Kulithalai · Mechanical Components & Spares · open
Key facts
- Tender value: ₹5.0L
- EMD: ₹5K
- Published: 18 Sep 2026
- Closing date: 05 Oct 2026
- Status: open
- Ministry: MAWS
Description
Maintenance and Repairs works to mini power pump and hand pump at ward no.1 to 24 in Kulithalai Municipality
Eligibility & requirements
- Startup relaxation: No
- MSE relaxation: No
New to these terms? Read how tender eligibility criteria work.
Commercial terms
- Bid type: Item Rate
- Make in India (MII): No
- MSE preference: No
Line items (8)
- Attending repairs to deep well handpumps for borewells inclusive of removal of G.I. Pipes, Plunger rods, Cylinder and re-erection of hand pumps inclusive of lowering the GI Pipes Plunger rods cylinder, jointing etc. Upto 30m — Qty: 20 Nos.
- Supply and delivery of clear water vertical wet type submersible pump conforming to IS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase 230 V+/- 10 %,50 HZ +/-5 %. Single phase submersible pumpset as per is 8034/2002 without panel board - 20X70 (LPM x Head in m) — Qty: 5 Nos.
- Removal of submersible pumpsets and its accessories from borewell/ open well for attending repairs 50% of the rates Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. Upto 5HP — Qty: 12 Nos.
- Re-erection of of submersible pumpsets and its accessories from borewell/ open well for attending repairs 50% of the rates Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. Upto 5HP — Qty: 12 Nos.
- PVC insulated and sheathed 3 core flat type copper cable conforming to IS 694/1990 and as amended thereafter 1.5 sq.mm — Qty: 30 M
- Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V on 7/20 GI bearer wire for service connection mains (SD 65) — Qty: 60 M
- Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/single Phase/50HZ(± 5%) and 230 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). Single phase panel board with two level guard and auto start for 1 HP — Qty: 5 Nos.
- Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V on 7/20 GI bearer wire for service connection mains (SD 65) — Qty: 60 M
1 tender document(s) available — sign up to download.
Related tenders
- Ventury as per MCW carriage repair workshop drawing No. MW-M-1-16 ALT.-2 Item No.-B ( 4, 5, 6 ) in assembled condition. — Mechanical Components & Spares · Rajasthan · ₹8.0L
- Dial Snap Gauge, Range 125-150 mm & Dial Snap Gauge, Range 150-175 mm — Mechanical Components & Spares
- NYLOC NUT HEX FOR WAG-9 HC — Mechanical Components & Spares
- Bevel Gear of Tap Changer N32 to M/s. REPL's Pt. No. - S1449 or similar to RDSO's Drg. No. - SKEL-4620 Sheet - 1 & 2 for WAG7 Locos. — Mechanical Components & Spares · West Bengal
- Set of gaskets for MRB — Mechanical Components & Spares
- Equaliser spring seat for WAG 5 locos — Mechanical Components & Spares
- Brake caliper unit leverage ratio 2.48 for LHB Power Car without brake cylinder to FTRTIPL Part. No. 090002000. — Mechanical Components & Spares · Uttar Pradesh
- Tecspak pad of Side Bearer — Mechanical Components & Spares