KMC/GRBU/T16R/26-27
Kolkata Municipal Corporation · Kolkata, West Bengal · Repair, Maintenance & AMC Services · open
Key facts
- EMD: ₹6K
- Published: 04 Nov 2026
- Closing date: 18 Nov 2026
- Status: open
- Status as of: 08 Nov 2026 00:09 UTC
- Department: Sewerage & Drainage Department
- Office: Dy. CE(M) (Sewerage & Drainage), 5, S. N. Banerjee Road, Kolkata –13
Description
Complete servicing and overhauling of the LT Transformer and main LT incomer, including allied re-installation works at Monikhali DPS under GRBU. Work is to be completed within 10 days from the work order. The tender requires an earnest money deposit of Rs. 6,000.
Eligibility & requirements
- Startup relaxation: No
- MSE relaxation: No
- Documents required: Trade/professional license under Section 199/200 of the Kolkata Municipal Act, 1980, Declaration regarding interest or share of a Municipal Officer or Servant in the tenderer's business, Declaration regarding relationship or close connection by marriage with the Mayor, Deputy Mayor, Aldermen, Councillors or Corporation officers, Contract labour license under the Contract Labour (Regulation and Abolition) Act, 1970 and West Bengal Contract Labour (Regulation and Abolition) Rules, 1972, as and when necessary
New to these terms? Read how tender eligibility criteria work.
Commercial terms
- Bid type: Item Rate
- Evaluation: The fairness of the quotation and past conduct of the contractor will be taken into consideration; the Corporation is not bound to accept the lowest or any tender
- Make in India (MII): No
- MSE preference: No
Line items (12)
- Discharging the primary and secondary side of transformer properly by earth rod and all the cable have to be dismantled by proper marking after taking the power supply off. — Qty: 1 item
- Dismantling of top cover, side cover, tap changing switch etc of the transformer. — Qty: 1 item
- Thorough cleaning & removing of dust of core &coil assembly, tap changing switch etc by CTC with the help of soft brush, clean cloth with hot air jet pressure after dismantling of HV connections from bushing terminal end of inside transformer as per direction of EIC. A) Check and ensure that HT tap links of all the three phases are at same position and fully tightened and locked B) Check and ensure that all HT connection nuts,bolts are fully tightened and locked. C) Check and ensure that the core, coil and its connections are thoroughly cleaned for any cobwebs, dust, dirt using air blower etc. D) The enclosure perforated sheet/mesh shall be cleaned thoroughly for cobwebs, dust, dirt ensuring adequate and proper ventilation of air through the same. — Qty: 1 item
- Re-insulation all the HT coil lead properly with insulating tape, varnish etc and reconnection of all the cable as per existing way and re-fixing the top cover, side cover, tap changing switch handle etc of the transformer after cleaning properly as per direction of EIC. A) Relays, its alarm and trip contacts, their circuits side covers, cable boxes, marshalling box, attend to any abnormality B) HT bushings examine for dirt deposit and for crack/damages clean with non-fibrous. — Qty: 1 item
- Magnetic balance and insulation test have to perform with proper tools upto the satisfaction of EIC. — Qty: 1 item
- High voltage test of the cables and equipment as per standard procedure. — Qty: 1 item
- Repairing and calibration of temperature scanner of transformer. — Qty: 1 item
- Making foundation of the LT Transformer incl. supply of c-section ms channel, angle of suitable dimension and fabrication job including labour charges and necessary items, components. — Qty: 1 item
- Making foundation of the main LT incomer incl. supply of c-section ms channel, angle of suitable dimension and fabrication job including labour charges and necessary items, components. — Qty: 1 item
- Making foundation of the intermediate switch no.2 incl. supply of c-section ms channel, angle of suitable dimension and fabrication job including labour charges and necessary items, components. — Qty: 1 item
- Finishing, laying and fixing compression gland of the 300sqmm 4 core power cable incl. supply of new socket(aluminum) with crimping method with necessary consumables. — Qty: 12 set
- Servicing and overhauling including small repairing job as required of the LT incomer panel with the help of Skilled personnel. — Qty: 1 item
2 tender document(s) available — sign up to download.
Related tenders
- KANDRI/ENGG/PUR/2026-27/ 1909 — Repair, Maintenance & AMC Services · Maharashtra · ₹1.4L
- AMC of Cooling Equipments of NPM — Repair, Maintenance & AMC Services · Odisha · ₹6.5L
- Repair and Maintenance Jobs in Unloading and Screening Area of RMHP — Repair, Maintenance & AMC Services · Odisha · ₹53.2L
- Service Engineering Visit for Maintenance of Van Mounted Cable Fault Locator — Repair, Maintenance & AMC Services · Odisha · ₹2.7L
- Emergency Visit for ABB Drives and Automation System — Repair, Maintenance & AMC Services · Odisha · ₹58.4L
- Cylinder Maintenance and Handling Service — Repair, Maintenance & AMC Services · Gujarat · ₹3.1Cr
- THREE YEAR ARC FOR SUPERVISION OF OVERHAULING/SERVICING OF M/S INSTRUMENTATION LIMITED (IL) VALVES AT BPCL KOCHI REFINERY — Repair, Maintenance & AMC Services · Kerala
- THREE YEAR ARC FOR SUPERVISION OF OVERHAULING/SERVICING OF M/S SAMSON VALVES & POSITIONERS, BPCL KOCHI REFINERY — Repair, Maintenance & AMC Services · Kerala