Construction of transformer platform at 33 KV S/S under XEN CD-VII, Jaipur
Jaipur Vidyut Vitran Nigam Limited · Jaipur, Rajasthan · Civil Works & Infrastructure · open
Key facts
- Tender value: ₹10.0L
- EMD: ₹20K
- Published: 06 Nov 2026
- Closing date: 13 Nov 2026
- Status: open
- Status as of: 08 Nov 2026 00:40 UTC
- Department: JVVNL - CMD||CE(O and M), Jaipur||SE-Civil
- Office: SE-Civil
Description
Construction of a transformer platform at 33 KV S/S under XEN CD-VII, Jaipur, based on PWD BSR (Bldg.) 2026. The BOQ includes civil, plumbing, lighting and electrical works.
Eligibility & requirements
- Startup relaxation: No
- MSE relaxation: No
New to these terms? Read how tender eligibility criteria work.
Commercial terms
- Bid type: Percentage
- Make in India (MII): No
- MSE preference: No
Line items (22)
- B-1/1.8:- Earth work in excavation by mechanical means (hydrolic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10sum on plan) including dressing of sides and ramming of bottoms lift up to 1.5 mtr taking out the excavated soil and depositing & refilling of jhiri with watering and ramming & disposal of surplus excavated soil as directed with in a lead of 50 mtr. All kinds of soil. — Qty: 50 Cum
- B-3/3.1.6:- Providing and laying in position cement concrete including curing compaction etc. Complete in specified grade excluding the cost of centrering and shutteting -All work up to plinth level (A) 1:4:8 (1 cement 4 coarse sand : 8 graded stone aggregate 40 mm Nominal size.) — Qty: 10 Cum
- M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). (3.1.2) — Qty: 2 Cum
- B-6/6.1.6:- Random rubble stone masonry for foundation and plinth in cement sand morter above 30 cm thick wall in:- Cement Mortar 1:6 ( 1-Cement : 6-Sand). — Qty: 76 Cum
- 4.9 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. — Qty: 15 Sqm
- 4.1 Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix — Qty: 11 Cum
- B-4/4.13.1:- Providing fabricating reinforcement for RCC work including straingtening, cutting, bending, placing in position and binding (including cost of binding wire) all complete upto floor Five level : cold twisted deformed bars (IS:1786). — Qty: 865 Kg
- B-9/9.2:- Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: — Qty: 345 Kg
- B-12/12.3:- Plaster on new surface on walls in cement sand morter 1:6 including racking of joint etc. Complete fine finished (a) 12.3.2 :- 20 mm thick. — Qty: 75 Sqm
- 2.2.3 /S-2 P & F G.I. pipe (External work) with G.I. Fittings excluding union (IS: 1239 Mark) including trenching & refilling earth etc (A) 25mm dia nominal bore 'B' class — Qty: 120 RM
- 2.7.3 /S-2 P & F Bib cock (IS: 8931 Mark), Superior quality of approved make: (A) C.P. brass bib cock 15mm nominal bore. — Qty: 4 No.
- 2.12.1/S-2 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. inlet connection 15mm Brass(Is: 8931 marked) — Qty: 4 No.
- 2.15.3 /S-2 P & F Full - way Valve (IS: 778 Mark) or wheel valve of approved make: (A) Gun metal 25 mm nominal bore — Qty: 6 No.
- 2.32.3 Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size : (A)25mm dia nominal bore — Qty: 6 No.
- 3.16.3 /S-3 P & F rigid PVC pipe ( IS: 4985 make) class II/(4 Kg./Cm2). Approved quality /make including jointing the pipe with solvent cement rubber ring and lubricant. (A) 110 mm dia — Qty: 20 RM
- 18.12.6 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing and secondary lens on each LED/ integrated lens diffuser without cover & should be High power LED of 3 to 5 watt each . The System efficacy >=135 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 — Qty: 12 Nos.
- 18.19.3 Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. 32 mm Dia. — Qty: 12 RM
- 11.2.1.1 Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size. 4.0 Sq. mm X 2 core (11.2.1.1) — Qty: 200 RM
- Disposal of Rubbish unwanted material dismantelled material away from site at appropriate place including all lead and lift, loading unloading, transportation, labour etc as per direction of Engineer in charges. — Qty: 30 P.Cum
- Stacking of laid crusher broken ballast from yard screening & relaying of the same in the same yard as per specifications in layer not exceeding 15cm as per specifications including dressing etc. complete for all lead and lift complete as per direction of Engineer in CHarges. — Qty: 50 P.Cum
1 tender document(s) available — sign up to download.
Related tenders
- UNDER FRAME (LS & LWS PP) — Civil Works & Infrastructure · Tamil Nadu
- Renovation of Dharamshala in New Yadvindra Colony, ward no. 20 at Patiala. — Civil Works & Infrastructure · Punjab · ₹42.2L
- Lining/Relining of water course of Outlet R.D 6000-R of mr. no 4 of Newada Disty Village Talwandi Malik, Khattriwala Distt. Patiala — Civil Works & Infrastructure · Punjab · ₹60.0L
- Outsourcing of Labour Part for Erection, Testing Commissioning of New 11KVLT/HTLines on Rail/PCC Poles, Distribution T/Fs, Augmentation/Sagging of ACSR of HT/LT Lines, Cables laying, Guarding, Stay Setfor Various Works — Civil Works & Infrastructure · Punjab · ₹60.0L
- Macdamization of road surface at syed Kamalud din Colony wanganpora Eid gah Near UPHC from h/o Ali Mohd upto h/o Nasir Khalel. — Civil Works & Infrastructure · Jammu and Kashmir · ₹15.0L
- Operation of supply valves for the distribution pipe line for piped scheme Babaichya and Narwar with associated works, under jurisdiction of sub division rural, District Rural Division Ajmer (Excluding GST) — Civil Works & Infrastructure · Rajasthan · ₹3.3L
- Remodelling and renovation Pond Rara Sahib Chowk Somal kheri Np Maloudh — Civil Works & Infrastructure · Punjab · ₹22.3L
- CONST OF STREET BACK SIDE AMRALA PESTICIDE SHOP W-11 — Civil Works & Infrastructure · Punjab · ₹3.1L