Augmentation of street light from Main Gate No 1 to Main Gate No 3 via Gate No 2 Rose Garden to Botany department including all Poles Cables lights etc in PU Sector 14 Chandigarh
Panjab University · Chandigarh, Chandigarh · Electrical Equipment & Supplies · open
Key facts
- Tender value: ₹1.4Cr
- EMD: ₹2.7L
- Published: 28 Oct 2026
- Closing date: 19 Nov 2026
- Status: open
- Status as of: 04 Nov 2026 06:20 UTC
- Department: Electrical
Description
Augmentation of street lighting at Panjab University, Sector 14, Chandigarh, including supply, installation and commissioning of LED fixtures, poles, cables, distribution equipment, civil foundations and associated dismantling and reinstatement work.
Eligibility & requirements
- Startup relaxation: No
- MSE relaxation: No
New to these terms? Read how tender eligibility criteria work.
Commercial terms
- Bid type: Percentage
- Make in India (MII): No
- MSE preference: No
Line items (34)
- 4 way (4 + 12), Double door (Ref DSR 2.4.1) — Qty: 8 Nos
- Single pole (Ref DSR 2.10.1) — Qty: 96 Nos
- Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.(Ref.DSR 5.1) — Qty: 90 Nos
- Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (Ref DSR 5.18) — Qty: 5500 rmt
- 63 mm dia (OD-63 mm & ID-51 mm nominal) (Ref DSR 15.15.1) — Qty: 400 rmt
- 63 mm dia (OD-63 mm & ID-51 mm nominal) (Ref DSR 15.16.1) — Qty: 5600 rmt
- 45 Watt (Ref DSR 8.13.11) — Qty: 73 Nos
- 90 Watt (Ref DSR 8.13.14) — Qty: 33 Nos
- 120 watt (Ref DSR 8.13.16) — Qty: 74 Nos
- 150 watt (Ref DSR 8.13.17) — Qty: 94 Nos
- Labour charges for horizontal boring 1 Mtr. Below ground level for laying of DWC pipe including cost of 2 Nos. pit digging and refilling complete in all respects to entire satisfaction of the EIC (Ref N.S.) — Qty: 400 rmt
- provided with rubber gasket to avoid entry of other insects etc. The top of the pedestal shall be covered with canopy made out of 16 G M.S. sheet projected outside to avoid entry of water. Four No. supporting members each of size 50mm x 6mm thick according to cubical size shall be welded for mounting switcher gear i.e. MCCB, BBC, Timer, Contactor and energy meter etc. The Pedestal shall be painted with two coats of P.O. red paint after applying one coat of red oxide. One No. The letter 'Street Light Pedestal.' in 4" size shall be written on the front door of the Pedestal. The pedestal will be housed on CC foundation, Snowcem and platform of size 750mm deep (300mm underground and 450 mm above ground x 960 mm long x 410 mm wide including sufficient number of DWC pipe size of 51/63mm pieces to facility to entire the main cable and the circuit cable. The work shall be executed to the entire satisfaction of EIC. (N.S.) — Qty: 8 Nos
- Supply & Erection of 4 pole, 36 kA, 100 Amp MCCB with fixed thermal and magnetic release for overload and short circuit protection, having Ics =100% of Icu with positive isolation. It includes the cost of Steel enclosure for MCCB. The MCCB is to be fixed in the feeder pillar complete in all respects. The work shall be executed to the entire satisfaction of EIC. (N.S.) — Qty: 8 Nos
- 4 core 16 sqmm — Qty: 7900 rmt
- S/E/T/C of 3 core 1.5 sqmm flexible Copper conductor, PVC insulated and FR PVC Sheathed, Copper Conductor confirming to IS-694:2010 within the street light poles and within the bracket fitted on pole, complete in all respected to the entire staisfaction of EIC. (Ref N.S.) — Qty: 2500 mtr
- Supply and erection of 9 mtr. Hot Dip Galvanized pole of Octagonal cross section continuously tapered made out from high tensile steel of minimum thickness 3 mm complete with the, Base plate 260 X 260 X 16 mm alongwith inbuilt locable junction box which should be operated with single key with connectors of Elamax/ Wago/ Essen/ Connectwell make for cable termination and two or three terminal with on no. 6 Amp SPMCB 'C' Curve rating for each luminarie. The junction box cover is to be welded with extra steel strip ring around the pole for prevention of junction box cover from theft. The octagonal pole should have diameter across from the dimension of base and top should be minimum 155 mm and 70 mm A/F (Across face). The junction box cover bottom opening should be minimum 1 meter above the base platei.e. Door evelvation should be 1000mm & door cutout be of 500mm. The size of poles & foundation bolts shall be suitable to withsatnd the maximum wind speed/ pressure as per IS-875 (PART 3): 201 — Qty: 66 Nos
- Supply and erection of 7.0 mtr Hot Dip Galvanized pole of Octagonal cross section continuously tapered made out from high tensile steel of minimum thickness 3 mm complete with the, Base plate 260 X 260 X 16 mm alongwith inbuilt locable junction box which should be operated with single key with connectors of Elamax/ Wago/ Essen/ Connectwell make for cable termination and two or three terminal with on no. 6 Amp SSPMCB 'C' Curve rating for each luminarie. The junction box cover is to be welded with extra steel strip ring around the pole for prevention of junction box cover from theft. The octagonal pole should have diameter across from the dimension of base and top should be minimum 155 mm and 70 mm A/F (Across face). The junction box cover bottom opening should be minimum 1 meter above the base plate i.e. Door evelvation should be 1000mm & door cutout be of 500mm. The size of poles & foundation bolts shall be suitable to withsatnd the maximum wind speed/ pressure as per IS-875 (PART 3): — Qty: 121 Nos
- Supply and erection of 6.0 mtr Hot Dip Galvanized pole of Octagonal cross section continuously tapered made out from high tensile steel of minimum thickness 3 mm complete with the, Base plate 220 X 220 X 16 mm alongwith inbuilt locable junction box which should be operated with single key with connectors of Elamax/ Wago/ Essen/ Connectwell make for cable termination and two or three terminal with on no. 6 Amp SSPMCB 'C' Curve rating for each luminarie. The junction box cover is to be welded with extra steel strip ring around the pole for prevention of junction box cover from theft. The octagonal pole should have diameter across from the dimension of base and top should be minimum 155 mm and 70 mm A/F (Across face). The junction box cover bottom opening should be minimum 1 meter above the base plate i.e. Door evelvation should be 1000mm & door cutout be of 500mm. The size of poles & foundation bolts shall be suitable to withsatnd the maximum wind speed/ pressure as per IS-875 (PART 3): — Qty: 40 Nos
- Single arm bracket 1000mm overhang (including reducer) — Qty: 73 Nos
- Double arm bracket 1500mm overhang (including reducer) — Qty: 14 Nos
1 tender document(s) available — sign up to download.
Related tenders
- SUPPLY OF V.F TRANSFORMER OF RATIO 470:600 OHMS (CYLINDER TYPE) — Electrical Equipment & Supplies · Madhya Pradesh
- Handheld Rechargeable Pocket Torch — Electrical Equipment & Supplies · Madhya Pradesh
- Procurement of Digital Dial Indicator and Stainless Steel Flexible Magnetic Base stand — Electrical Equipment & Supplies
- Erection of lighting line for mine lighting purpose at R-VI seam and various places coal depot, DDU, Agent office at Khottadih OCP — Electrical Equipment & Supplies · West Bengal · ₹9.9L
- Procurement of Electrical instruments/Equipments and machinery for Electrical, Repairing, Fabrication and other electrical works at Gumgaon Mine — Electrical Equipment & Supplies · Maharashtra · ₹1.9L
- Work of re-organisation of generator line in different rooms of Bankola Area offiece. — Electrical Equipment & Supplies · West Bengal · ₹1.5L
- Diversion of 6.6KV O/H Line at Jharna Face due to increase in water level and widening of Haul Road for feeding power to 4000GPM Motor Pump in SOCP Muraidih AMP Colliery. — Electrical Equipment & Supplies · Jharkhand · ₹1.2L
- Installation of earth pits at different substations of Jambad Colliery — Electrical Equipment & Supplies · West Bengal · ₹5.1L